EFCO surface lapping machines are excellent for lapping individual or series components, face seals, valve seats, gates, etc.. Worn components, such as valve seats, mechanical shaft seals, disks, etc., can be re-lapped in repair workshops and at refurbishment companies. Automatic and finely adjustable lapping compound feed as well as freely adjustable lapping table speed guarantee high quality lapping results.
Our Firesure flowmeters are designed for sprinkler fire pump testing. They are approved by LPCB and are simple and quick to install. We offer both our standard Firesure meter and our Firesure X meter, which allows for remote mounting, in a range of sizes suitable for both horizontal and vertical pipes and in a wide range of flows. They are both available with either flanged or grooved connections. These flowmeters are also available with FM approval. pdf datasheet
Our Firesure FM flowmeters are designed for sprinkler fire pump testing. They have FM approval and are simple and quick to install. Firesure FM is available in a range of sizes suitable for both horizontal and vertical pipes and in a wide range of flows scaled in both USGPM and dm³/min. They are available with either between flange or groove connections. These flowmeters are also available with LPCB approval. pdf datasheet
Our Firesure Duo-Groove flowmeters feature a combined USGPM and L/min tube suitable for both LPC and FM approved installations. Key Features & Benefits Single combined l/min and USGPM tube. Suitable for LPC and FM installations. Stable easy to read flow indication. pdf datasheet
The universal converters are used as flow indicators and for batching control of miscellaneous liquids: water, industrial liquids, fuel etc.. These converters are designed for industrial environments. Four versions are available: flow totaliser F113, differential flow measurement F116/F127 with temperature compensation and batching control F131 (non explosive environment) and F131 Exi (explosive environment). pdf datasheet
Float level switches are used for point level detection of liquids in all type of vessels. Operation without external power, side or top mounting, wide temperature and pressure ranges, various process connections, stainless steel wetted parts, Ex version and marine certificates make it a universally applicable level switch. pdf datasheet
The electronic DS pressure switch with ceramic sensor, intrinsically safe for gases (Exia), Pressure ranges up to 600 bar pdf datasheet DS401 pdf datasheet DS201 pdf datasheet DS230
The electronic universal DS pressure switch with stainless steel sensor, intrinsically safe for gases (Exia), Pressure ranges from 0...100 mbar to 0...600 bar pdf datasheet DS400 pdf datasheet DS200 pdf datasheet DS202
The DS4 electronic pressure switch for Silizium sensor for pneumatic applications. Pressure ranges 0...10 mbar to 0...1 bar and vacuum -1...0 bar pdf datasheet
The electronic DS214 high pressure switch with pressure ranges from 0...600 bar to 0...2200 bar pdf datasheet
The electronic DS210 low and vacuum pressure switch. Pressure ranges 0...10 mbar to 0...1 bar and vacuum -1...0 bar pdf datasheet
The electronic DS-P pressure switch Stainless steel diaphragm, flush, for hygienic, paint, chemical, high viscosity applications pdf datasheet DS200P pdf datasheet DS400P
The DIESEL SWITCH is a fuel management system which helps you to comply with MARPOL regulation. It controls fully automatically the changeover and blending process on board your good vessels and will manage additional processes within your fuel system. Protect your engine - no human risk! Save ship operation - change over or blending process in maneuvering areas. pdf datasheet
Vibrating level switches utilise a piezoelectric crystal to oscillate a blade at its fundamental frequency (also referred to as the natural resonance). When the blade of the probe comes into contact with the process media the natural frequency of oscillation is dampened; the electronics sense the change in frequency which causes the unit to switch. pdf datasheet
Domino flow measurement of liquids in chemical, pharmaceutical, cosmetic and other industries. Batching, dosing and filling operations. pdf datasheet
Precision Pressure Transmitter DMP 334i, adjustable ranges from 0...600 bar to 0...2200 bar, accuracy 0.1% FS pdf datasheet
Precision Pressure Transmitter, adjustable ranges from 0...400 mbar to 0...600 bar, accuracy 0.1% FS, intrinsically safe Exia option pdf datasheet
The ultra-high-pressure transmitter type DMP 304 with rugged stainless steel housing for applications with highest demand on precision and reliability. DMP 304 series is based on a compensated strain gauge, bonded onto a stainless steel diaphragm - adjustable ranges from 0...2000 bar to 0...6000 bar, accuracy 0.5% FS (opt 0. 25%FS) pdf datasheet
The CONTOIL® DFM-BC is the suitable computer and display, which covers all direct and differential applications in fuel metering. It can be used for all available flowmeter sizes. - Robust, vibration approved synthetic material housing - Total consumption, daily total, actual consumption - Service-functions: parameter read out for each flow meter - Log-book: storage of the configuration and messages of both flow meters pdf datasheet
The liquid density meter of the DIMF series is used for continuous measurement of the density/concentration of liquids or liquid mixtures. The proven tuning fork principle guarantees a high acccuracy with very good long term stability.The robust design ensures reliable operation even under harsh operating conditions. pdf datasheet
The Deltaflux Orifice Meter is ideal for direct flow indication of high liquid or gas flows in large pipe sizes. It offers an economic, easy to use and low maintenance solution that does not require external powering. Key Features & Benefits High flows Direct reading Between flange connections Compact construction pdf datasheet
Novaris DB Protectors provide protection for serial protocol systems in RS232 and RS485 applications. These units are housed in a headshell enclosure. The DB Protectors have a 90V earth isolation to prevent ground loops.
To measure heating fuel consumption by oil burners (for example, in heating boilers, industrial furnaces, tar processing plants), Mineral Oils, Consumption monitoring and optimization (ships, generators and large vehicles, etc.), Manual Dosing/Batching pdf datasheet
To measure heating fuel consumption by oil burners (for example, in heating boilers, industrial furnaces, tar processing plants), light and extra light mineral Oils, Consumption monitoring and optimization (ships, generators and large vehicles, etc.) pdf datasheet
Centrifugal Air Separators are used to avoid measuring errors that result from air or gas contained in liquids measured with volumetric and mass flow meters. pdf datasheet
For the generation of high pressure or the compression of air or nitrogen and storage in the integrated pressurised bottle at up to 350 bar (approx. 5075 psi).
Featuring 5 digits of rate and 8 digits of total, the BAT R/T Millennium edition is a battery powered or loop powered indicator capable of accepting magnetic pickup, DC pulse and switch closure inputs from pulse producing flowmeters. The unit can be ordered with an optional 4-20mA output. The BATRT-M uses the 4-20mA loop to provide power when this output is used. pdf datasheet
Featuring 4.5 digits of rate and 8 digits of total, the BAT RAT-M is a battery powered indicator with flow rate alarm output. It is capable of accepting magnetic pickup, DC pulse and switch closure inputs. The unit can be ordered with an optional 4-20mA output. The BAT RAT-M uses the 4-20mA loop to provide power when this output is used. pdf datasheet
Featuring 5 digits of resetable total and 8 digits of grand total, the BAT D/T Millennium is a battery powered indicator capable of accepting magnetic pickup, DC pulse and switch closure inputs from pulse producing flowmeters. A scaled pulse output is standard. A 4-20mA loop and/or linearization is optional. pdf datasheet
The temperature economical transmitter AT-2 is applicable to converting resistance of temperature sensor to standard current signal 4...20mA. pdf datasheet
The ASM is a portable lathe for cutting out welded seat rings in valves. It is suitable for use on site and in the workshop, in nuclear power plants, in conventional power plants, for valve service, for the chemical and petrochemical industry, in steel construction in shipyards and oil fields.
The AS pressure transmitter for gases, vapors and liquids, Fixed ranges: 0 ÷ 1; 0 ÷ 2,5; 0 ÷ 6; 0 ÷ 10; 0 ÷ 16; 0 ÷ 25 bar - Accuracy 0.4%, 4-20 mA output pdf datasheet
The Aplisens Smart Temperature Transmitter APT-2000 ALW from Europe is applicable to the measurement of temperature. The RTD PT100 sensing element ranges from -200°C to 550°C, (TC type K from -40°C to 550°C). The device is suitable for custody transfer measurement of gas. pdf datasheet
The APRE-2200 ALW transmitter with 2 diaphragm seals from Europe is applicable to the measurement of differential pressure of gases, vapor and liquids for filter-loss and pressure tank applications pdf datasheet
The APR-2200 ALW transmitter with 2 diaphragm seals from Europe is applicable to the measurement of differential pressure of gases, vapours and liquids. pdf datasheet
Smart differential pressure transmitters with direct diaphragm seals pdf datasheet
The APR-2000 ALW transmitter from Europe is applicable to the measurement of differential pressure of gases, vapours and liquids. Range: min -7 to 7 mbar, max 0-70 bar pdf datasheet
differential pressure transmitter for level measurement in pressure tanks based on 2 absolute pressure transmitters pdf datasheet
The APIS positioner is a final control element intended for control valves.It is intended for cooperation with pneumatic membrane and piston single and double-acting actuators with linear and rotational movement. It allows quick and precise controlling of displacement of actuator piston rod using analog or digital control signal.The positioner is controlled by a standard signal from two-wire 4..20 mA current loop or digitally in accordance with the HART 6 specification. It can be also equipped with a two-wire, current (4..20 mA) position transmitter of piston rod of the associated actuator. Current circuit of position transmitter is galvanically isolated from the input circuit of the control signal.The positioner can cooperate both with straight and reverse acting pneumatic actuators. The positioner can cooperate with single-acting actuators manufactured by Polna S.A., Samson, Arca Regler, Spiral-Sarco and double-acting actuators manufactured by Prema Kielce, Air Torque, Festo, Ebro Armaturen, El-0-Matic and by other manufacturers using proper mechanical coupling components. pdf datasheet
The APLISENS APC-2000 ALW Smart Pressure Transmitter from Europe gives accurate measurement for Absolute, Gauge and Vaccum pressure of gases, vapors and liquids. Range: min -7 to 7 mbar, max 0 to 1000 bar pdf datasheet
Mobile Configurator for Android based devices to communicate and transfer data with Aplisens transmitters. download PDF Hart Communication Tools
The mechanical Bourdon Tube pressure switch for rough working conditions with aggressive fluids or high temperature. Range: vacuum and compound pressure up to 600 bar pdf datasheet
The mechanical diaphragm pressure switch with for vacuum and compound pressure upto 160 bar pdf datasheet 03.40 pdf datasheet 03.27
The mechanical diaphragm pressure switch with ranges from 0...1 bar to 0...25 bar and vacuum pdf datasheet
The Hycontrol Sonarflex sludge blanket and interface controller is a microprocessor-based transmitter, combined with an appropriate RVS sonar transducer and a cleaning mechanism. It can be programmed via an easy menu-driven keypad or remotely via a PC. It is used to measure the blanket level in primary sedimentation tanks or the RAS Blanket and FLOC/FLUFF layers in secondary and final clarifiers. pdf datasheet